Introduction

Exporting Ultrasonic Data as a .CSV File to Generate Custom Reports

Reports are the end result that inspection companies offer their customers. A clear and detailed report can differentiate one company from another by providing more comprehensive results and illustrating concepts that may be difficult to grasp for the end-user.

Challenges in creating a custom report

Since there can be as many types of reports as there are customers, it can be challenging to find one format that fits the needs of every customer. For example, the engineers might need specific calculations to estimate the remaining life of a component to provide their assessment and make educated decisions. Being able to produce this information easily could become critical in some projects.

Solution: export the C-scan

The C-scan export feature is a way to generate a .CSV format file directly from an or from OmniPC™ software. It enables the inspector to export every single data point from an inspection to create a document that contains the entirety of the inspection information.

Users can access the export data function by right clicking in OmniPC software or pressing and holding the C-scan window in an OmniScan flaw detector running MXU 4.2 software and later. A list will appear containing the “Export” option. Once the user clicks or presses “Export,” the .CSV file is generated and saved either on a computer (if using OmniPC software) or on an SD card (if using an OmniScan flaw detector).

Exporting Ultrasonic Data as a .CSV File to Generate Custom Reports

Figure 1. The export option can be selected while in the C-scan view. Right click in OmniPC software or press and hold on the OmniScan screen.

Advantages

The .CSV file can be opened in a variety of programs, such as Microsoft® Excel® software. In Excel software, conditional formatting can be used to make detection and analysis easier and enable the user to look at the same information in different ways.

Exporting Ultrasonic Data as a .CSV File to Generate Custom Reports

Figure 2. A .CSV file opened in Excel software with conditional formatting in color to display corrosion.

Exporting Ultrasonic Data as a .CSV File to Generate Custom Reports

Figure 3. A .CSV file opened in Excel software with conditional formatting in 3D to display corrosion.

Exporting Ultrasonic Data as a .CSV File to Generate Custom Reports

Figure 4. Different options to display data in 3D.

Features such as automatically listing the position of a pit and showing average thickness, minimum thickness, and the proportion of an area under a predefined thickness threshold can easily be implemented using third-party software. The .CSV file format is compatible with a variety of NDT programs as well as pipeline burst pressure calculators.

Conclusion

The export C-scan option in OmniPC™ software or onboard the OmniScan® flaw detector software (version 4.2 and later) enables users to view and analyze their inspection data and opens up possibilities for displaying important information and providing remaining life calculations.

관련 제품


https://main--eds-evident-website--evident-scientific.aem.live/ko/omni-pc/

옴니PC 소프트웨어

이 새로운 소프트웨어는 옴니스캔 데이터 분석을 위한 가장 효율적이고 저렴한 선택으로, 옴니스캔 온보드 소프트웨어에 제공되는 것과 동일한 분석 도구를 갖추고 있으며, 개인용 컴퓨터에서 실행할 수 있는 유연성이 더해졌습니다.


https://main--eds-evident-website--evident-scientific.aem.live/ko/omniscan-sx/

옴니스캔 SX

단일 그룹인 경량 옴니스캔 SX는 읽기 쉬운 8.4인치(21.3cm) 터치 스크린을 갖추고 있으며, 비용 효율적인 솔루션을 제공합니다. 옴니스캔 SX는 SX PA와 SX UT의 두 가지 모델로 제공됩니다. SX PA는 UT 전용 SX UT와 마찬가지로 P/E, P-C 또는 TOFD 검사를 위한 재래식 UT 채널을 장착한 16:64PR 장치입니다.