애플리케이션 노트
침지 탱크 검사 시스템
This single system supports both phased array and conventional UT technology and it performs immersion tank testing and manual inspection.Owing to the complete customer support provided by Evident, the capacity for customization and the wide range of products it can inspect, this system is sure to meet your needs.
The immersion tank testing system for ultrasonic inspection developed by Evident is an automatic scanning system that analyzes and evaluates the volume of the inspected part and the weld joint with high accuracy and speed. Customizable analysis software generates an image of the acquired data, automatically calculates and evaluates the defect area, processes 3D imaging, displays defect distribution, and assigns a pass/fail grade.
Features of the Evident Immersion Tank Testing System
Comprehensive support from a world leader in phased array technology
Because of its extensive experience with phased array systems and portable instruments, Evident is capable of ensuring that your application and inspection needs are met and that you receive the necessary training.
The immersion tank testing/manual inspection system features both phased array and conventional UT testing, improving the performance rate.
Inspection is not limited to the immersion tank with this system because the phased array flaw detector can be removed and it is portable, which gives you the flexibility to inspect very large sized objects and materials of various shapes. You can also use it with a variety of scanners, probes, and software. You can also choose between conventional UT and phased array according to your situation. Because of the versatility offered by this one system, it can improve operating rates and performance, and it is cost effective.
You can configure and customize your system according to your needs—from low cost to high-end.
Depending on your needs, Evident recommends which UT flaw detection hardware features and software customization to select from the broad range of choices available, such as one-button operation. The Immersion Tank Testing System can be integrated into your current facility to update and reconfigure old scanners and phased array systems.
Reduces inspection time though the use of phased array technology
Conventional UT Inspection/Phased Array Inspection
Phased array instruments can scan a 200 x 200 mm area, at 0.5 mm resolution and 50 mm/s inspection rate, in less than 1 minute with one line wide scan. Conventional UT instruments would take approximately 25 minutes to inspect the same area.
Application Example
- Disbond and void testing for composites (including CFRP) and anode materials
- Automotive industry part research and development, such as aluminum ingots, prototype testing, manufacturing inspection, inline quality inspection, etc.
System Overview
scanner for bent plate
scanner for pipe
phased array probes
Examples of customization capabilities:
- Scanning patterns can correspond to the part (for example, the standard X-Y axis scan → Y-X axis scan).1
- The analysis software can be customized.2
- The system’s size can be changed to suit the constraints of the installation location.
- Phased array probes can also be customized.
- Configurable for in-line inspection
- Retrofit capability for conventional equipment (example: reconfiguration of an old scanner and a phased array system)
1 According to the geometry of the sample, the scanning pattern can accommodate an X-Y scan, an X-Z scan and a Z-R scan.
2 We provide a data analysis that fits your needs, incorporating various external analysis software for your inspection application.
System Example
Specification example
Waveform processing software
(oscilloscope)
(16/64)
(16/128、32/128)
(16/128、32/128)
TomoView analysis software
(16/128、32/128)
Analysis software
(extended)
Frequency
Suitable for research applications
Creates cross-sectional images
Entry model for phased array
Comprehensive conditional settings
Analyses without external software
Comprehensive conditional settings
Advanced analysis with TomoView analysis software
Comprehensive conditional settings
Fully automated inspection with pass/fail determination by software extension
Other customizations
*OmniScan MX2 (PA1664), immersion tank testing system, TV2.10 Full 5L64‐I1 probe
A high performance package is also available for the automatic analysis of defects in parts in an in-line system.
For details about an Immersion Tank Testing System, please contact here.
0.5–35 MHz(UT)
Z axis from 100 mm
**The Immersion Tank Testing System is only available in Japan.
이 애플리케이션에 사용되는 제품
단일 그룹인 경량 옴니스캔 SX는 읽기 쉬운 8.4인치(21.3cm) 터치 스크린을 갖추고 있으며, 비용 효율적인 솔루션을 제공합니다. 옴니스캔 SX는 SX PA와 SX UT의 두 가지 모델로 제공됩니다. SX PA는 UT 전용 SX UT와 마찬가지로 P/E, P-C 또는 TOFD 검사를 위한 재래식 UT 채널을 장착한 16:64PR 장치입니다.
와전류 배열 시험 검사를 수행합니다. 테스트 구성은 브리지 또는 송수신 모드에서 작동하는 32개의 센서 코일(외부 멀티플렉서 사용 시 최대 64개)을 지원합니다. 동작 주파수는 20Hz에서 6MHz까지이며, 동일한 수집에서 여러 주파수를 사용할 수 있습니다.