Corrosion Inspection Scanners

Contact Us

Products

FlexoFORM

FlexoFORM

The innovative FlexoFORM scanner makes challenging pipe elbow corrosion inspection easier. The scanner's flexible phased array technology makes it possible to use a single probe to cover the entire range of pipe elbow diameters.

Read more

SteerROVER

SteerROVER

The SteerROVER is a fully automated, steerable motorized 2-axis scanner capable of performing corrosion mapping in remote locations. When combined with the HydroFORM or the DLA phased array corrosion mapping solutions, it is a powerful tool for C-scan imaging of remaining wall thickness and mid-wall anomalies.

Read more

MapSCANNER

MapSCANNER

The MapSCANNER is a semiautomated, 2-axis corrosion inspection scanner. When combined with the HydroFORM or Dual Linear Array (DLA) phased array corrosion mapping solutions, it is a powerful, efficient tool for C-scan imaging of remaining wall thickness and mid-wall anomalies.

Read more

MapROVER

MapROVER

The MapROVER is a fully automated, motorized 2-axis corrosion mapping scanner. When combined with the HydroFORM phased array corrosion mapping solution, it is a powerful tool for C-scan imaging of remaining wall thickness and mid-wall anomalies.

Read more

HydroFORM Scanner

An easy-to-deploy 2-axis encoding PA solution, the HydroFORM semiautomated scanner enables fast and reliable high-resolution data acquisition of large surfaces. To ease raster scanning, it’s equipped with X and Y encoders, a unique water column system, and coupling check and position indicators.

Read more

ChainSCANNER

ChainSCANNER

The ChainSCANNER™ solution facilitates manual inspection of pipes with outside diameters (OD) ranging from 76 mm to 965 mm (3 to 38 in.) Held by chain links instead of magnetic wheels, the scanner is well suited for weld or corrosion inspection on different types of materials using ultrasonic testing (UT), time-of-flight diffraction (TOFD), and phased array (PA) technologies.

Read more

GLIDER Scanner

GLIDER Scanner

The GLIDER scanner is a 2-axis (X-Y) encoding scanner for the manual inspection of slightly curved or flat composite surfaces. The scanner, held by suction cups is well suited for raster scanning. Technologies: ECA, EC, UT, PA.

Read more

VersaMOUSE Scanner

The VersaMOUSE™ is a scanner designed for linear encoded scans with a phased array probe. The integrated indexing button makes it ideal for 2-D mapping applications such as CFRP flat panel and corrosion inspections. The VersaMOUSE can perform an encoded one-line scan, followed by indexing of the position in the perpendicular direction. Another one-line scan can then be performed and juxtaposed to the previous scan. This process is repeated to produce a complete 2D map of the area of interest.

Read more

Mini-Wheel Encoder

The mini-Wheel Encoder is used for the positioning and dimensioning of defects in the scan axis. It can synchronize data acquisition with probe movement. It is also waterproof and compatible with Evident standard PA wedges.