Visual Inspection Solutions for Data Center Maintenance

Contact Us

Data centers house business-critical applications and data, so the servers inside generate enormous amounts of heat. As part of routine data center maintenance, the heating, ventilation, and air conditioning (HVAC) system must be strictly controlled to reduce the risk of damage caused by dust and higher temperatures and humidity.

With bright, clear imaging, various optical adaptors, and an optimized insertion tube, Evident IPLEX™ videoscopes enable efficient inspections of HVAC and chiller systems in data centers.

Bright, Clear Images

The PulsarPic™ image processor actively adjusts the brightness levels for a clear view of chiller tubes and steel pipes. WiDER™ image processing technology supports a wide dynamic range to maintain visibility in dark areas, even when the brightness is decreased, to avoid halation.

Optimize Your View with Optical Adaptors

Interchangeable optical adaptors deliver high-quality images of objects located from close distances to far areas.The optical adaptor with a 220-degree wide-angle view lets you observe both the front and back sides of a welded section at the same time.

Access Hard-to-Reach Spaces

Our Tapered Flex™ insertion tube optimizes stiffness and flexibility with TrueFeel™ responsive articulation for smooth insertion into complex pipes with bends.

Corrosive chiller tube

Corrosive chiller tube

Visual Inspection Kits for Data Center Maintenance

Our visual inspection kits include IPLEX videoscopes and other recommended tools for high-quality inspections of HVAC systems and chillers in data centers. Perform efficient inspections with videoscope accessories, such as:

  • Wide Range of Scopes: Our RVI kits include a range of scope lengths from 2–30 m (6.6–98.4 ft). The interchangeable scope design of IPLEX GX and IPLEX GAir videoscopes enable a quick switch to a longer or shorter scope that can reach the inspection target.
  • Scope Insertion Tools: We offer various accessories to assist and ease scope insertion into difficult-to-access areas or deeper targets.

Flexible guide tube for 7.5 m (24.6 ft) and 10 m (32.8 ft) scopes

Flexible guide tube for 7.5 m (24.6 ft) and 10 m (32.8 ft) scopes

Handheld Kit

IPLEX G Lite Videoscope

Learn More

Large 8-Inch Monitor Kit

IPLEX GX Videoscope

Learn More

Get All the Details

Get All the Details

Download the brochure now to learn more about our data center inspection kits.

Download

Extra-Long Kit

IPLEX GAir Videoscope

Learn More

For more information contact us.