Vanta Handheld XRF Analyzer

Instantly identify materials and their chemical composition from any location using the Vanta™ handheld XRF analyzer. The Vanta series delivers fast, accurate elemental analysis and material identification using smart and cloud-connected technology.

Vanta Handheld XRF Analyzer

https://adobeassets.wabtecint.com/content/dam/tnm/videos/PEAK_ALLOYS_MASTER.mp4

Vanta™ Handheld XRF Analyzer

Maximize Efficiency in the Field and Lab

Request Quote

Instantly identify materials and their chemical composition from any location using the Vanta handheld XRF analyzer. The Vanta series delivers fast, accurate elemental analysis and material identification using smart and cloud-connected technology.

Our next-generation Vanta handheld XRF analyzers are available in three versatile models—Vanta Max, Vanta Core, and Vanta Element. They combine the exceptional accuracy, speed, and durability of the Vanta series with improved ergonomics, a streamlined interface, and enhanced connectivity for greater productivity. All Vanta analyzers are backed by a three-year warranty for a low cost of ownership.

The Vanta Series

Vanta Max
  • Highest analytical capabilities
  • Robust analysis
  • Mining exploration
  • Mineral analysis
  • Soil testing
  • Environmental analysis

Vanta Core
  • Analytical excellence
  • Faster analysis
  • Alloy identification
  • Metals analysis
  • Precious metals analysis

Vanta Element
  • Uncompromising performance
  • Fast, basic analysis
  • Affordable alloy ID and metals analysis
  • Light element detection option

How Our Customers Use Vanta Handheld XRF


https://main--eds-evident-website--evident-scientific.aem.live/en/applications/vdm-metals-exceeds-client-expectations-with-vanta-handheld-xrf/

VDM Metals

VDM Metals, a global supplier of metals, employs multiple Vanta handheld XRF analyzers throughout their facility for end-to-end alloy identification.

More


https://main--eds-evident-website--evident-scientific.aem.live/en/insights/soil-analysis-discovery-combines-handheld-xrf-and-vis-nir-data

Texas Tech University

A Texas Tech University professor made an award-winning soil analysis discovery using our Vanta XRF analyzer.

Read Now


https://main--eds-evident-website--evident-scientific.aem.live/en/insights/artemis-testing-lab-identifies-authentic-artifacts-using-xrf-analysis

Artemis Testing Lab

Artemis Testing Lab relies on the Vanta XRF analyzer to evaluate the authenticity of artifacts for museums and galleries around the world.

Read Now


https://main--eds-evident-website--evident-scientific.aem.live/en/insights/carbon-steel-successhow-xrf-helped-id-an-ancient-helmet

Pawn Stars

Our Vanta XRF analyzer was used on the popular History Channel TV show Pawn Stars to ID an ancient helmet in seconds.

Read Now


https://main--eds-evident-website--evident-scientific.aem.live/en/insights/austin-hayes-ltd-safely-recycles-wooden-ammunition-boxes-using-handheld-xrf

Austin Hayes

Austin Hayes Ltd. used Vanta handheld XRF analyzers to safely recycle 20,000 wooden ammunition boxes.

Read Now

Key Benefits

Comfortable and Rugged for All-Day XRF Testing

With an enhanced ergonomic design, Vanta handheld XRF analyzers are a productive tool for extended use in the field and lab. Combined with their proven ruggedness and ease of use, Vanta analyzers can increase uptime in the toughest environments.

  • Balanced handle minimizes hand fatigue
  • Secure and comfortable grip for all-day testing
  • Built to pass a 4-foot drop test (MIL-STD-810G)
  • IP55/IP54 rated for resistance to water and dust
  • Standard three-year warranty protects your investment

Productive XRF Analysis Workflow

Designed with the technician in mind, the Vanta analyzer simplifies handheld XRF testing from start to finish to maximize user throughput. Work efficiently using a modern, intuitive interface and browser-based software option.

  • Review, share, and manage XRF results on a PC, tablet, or smartphone with an optional wireless connection for seamless data integration
  • Benefit from the latest features instantly thanks to automatic software updates
  • Enhanced application support with the option to add custom analytical capabilities
  • Access our Evident Connect cloud for seamless data management

Trusted Portable XRF Technology

Vanta handheld XRF analyzers are used by thousands of customers around the world in diverse applications. Building on proven performance, Vanta analyzers provide precision and accuracy for portable XRF analysis.

  • Vanta series’ proprietary Axon Technology uses ultra-low-noise electronics, enabling a higher X-ray count rate for fast, accurate, and repeatable results
  • Axon Technology provides remarkable test-to-test and instrument-to-instrument repeatability, so your first test is the same as your last test no matter what instrument you use

Software

Optimized for Your Workflow

Vanta handheld XRF analyzers have a variety of features so that you can customize and adapt your analyzer to fit your specific workflow. The analyzer’s software makes it simple to customize the device in the way that you want. Innovative software features enable you to get the most out of your analyzer for a fast return on investment.

Software Features That Deliver Fast ROI

Vanta handheld XRF analyzers feature innovative software features designed to maximize their capabilities.

  • SmartSort: automatically lengthens or shortens test time based on the material to save time; obtain aluminum grade results in as little as one second
  • Grade match messaging: real-time and/or pop-up messages with familiar trade or grade names or special handling instructions to reduce user training and increase efficiency
  • Nominal value: automatically identifies the likely presence of elements invisible to XRF based on grade specifications
  • Residual library: set a maximum tolerated concentration for residual elements in grade families
  • On-screen grade comparison: compare close grades side-by-side to know which alloy is the best match with nominal and residual values
  • Empirical Mode for advanced analysis

Connected and Cloud Capable

  • Wireless connectivity: access our Evident Connect cloud or other devices with optional Wi-Fi® and Bluetooth®.
  • Embedded GPS: pair test results with precise GPS* coordinates to document and map the location of elements
  • Streamlined reporting: combine GPS data, XRF test results, and images from the optional 5-megapixel panoramic camera for inclusive archiving and streamlined reporting

*Vanta Max model only

Inserting image...

Customizable for Efficient Fleet Management

Vanta analyzers are designed to enable efficient fleet management in conjunction with Vanta Desktop PC software.

  • Customizable UI: set up the interface the way you want to maximize throughput and efficiency.
  • Favorites: choose what tests or features appear on the analyzer’s home screen.
  • Username and password: managers can create unique usernames and passwords for each user.
  • Push custom setups: easily transfer custom setups and specifications to your entire analyzer fleet.
  • Simple data export: data are quickly and easily exported via a USB flash drive, Wi-Fi, or Bluetooth.

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Evident Corporation is under license.

Specifications

Vanta Specifications

Dimensions (W x H x D)
10.4 × 29.6 × 24.1 cm (4.1 × 11.6 × 9.5 in.)
Weight
Max: 1.9 kg (4.17 lb) with battery, 1.67 kg (3.67 lb) without battery
Core: 1.85 kg (4.06 lb) with battery, 1.62 kg (3.56 lb) without battery
Element-S: 1.84 kg (4 lb) with battery, 1.61 kg (3.55 lb) without battery
Element: 1.71 kg (3.77 lb) with battery, 1.48 kg (3.26 lb) without battery
Excitation Source
X-ray tube with an application-optimized anode material.
Max: 4 W with 8–50 kV rhodium anode
Core: 4 W with 8–50 kV silver, 8–40 kV rhodium, or 8–40 kV tungsten anode
Element-S: 4 W with 8–50 kV silver anode
Element: 2 W with 8–35 kV tungsten anode
Primary Beam Filtration
Max and Core: 8-position autoselected filter per beam per mode; optional collimation to 3 mm diameter beam spot
Element-S: 4-position filter wheel
Element: Fixed aluminum filter
Detector
Silicon drift detector with a high-sensitivity graphene window
Power
Removable 14.4 V Li-ion battery (with hot-swap capability on Max only) or 18 V power transformer 100–240 VAC, 50–60 Hz, 70 W max
Display
800 × 480 (WVGA) LCD with capacitive touch screen supporting gesture control
Operating Environment
Temperature range for Max and Core: -10 °C to 50 °C (14 °F to 122 °F), and continuous full duty cycle with optional fan
Temperature range for Element: -10 °C to 45 °C (14 °F to 113 °F)
Humidity: 10% to 90% relative humidity non-condensing
Drop Test
Military Standard 810-G 4-foot (1.2 m) drop test
IP Rating and Detector Shutter
Max and Element: IP54* dust protected and protected against water splashing from all directions
Core: IP55* dust protected and protected from low-pressure water jets from all directions
Max and Core: Solid detector shutter to help prevent detector damage
*In-use position
Pressure Correction
Max and Core: Built-in barometer for automatic altitude and air density correction
GPS
Max: Embedded GPS / GLONASS receiver
Operating System
Linux
Cloud enabled with user fleet manager capability
Data Storage
microSD slot with removable 1 GB industrial SD card included
USB
(2) USB 2.0 Type-A ports for accessories such as Wi-Fi, Bluetooth, and USB flash drives
(1) USB 2.0 Type Mini-B port for connection to computer
Wi-Fi®
Supports an 802.11 b/g/n (2.4 GHz) cable optional USB adapter
Bluetooth®
Supports Bluetooth with an optional USB adapter
Aiming Camera
Max and Core: Optional full VGA CMOS camera
Panorama Camera
13-megapixel CMOS camera with autofocus lens (optional)
Warranty
Three-year warranty
Selected Optional Accessories
Max and Core: Field Stand, Soil Foot, Holster, Work Station, Weld Mask, Hot Heel, and Probe Shield
Element: Field Stand, Soil Foot, and Holster

*High-temperature performance may vary due to electrical component availability.

Applications

Vanta for Car Catalyst Recycling

Vanta™ handheld XRF analyzers provide fast, accurate measurement of the valuable platinum group metals (PGMs) palladium (Pd), platinum (Pt), and rhodium (Rh) found in car catalytic converter material. On-the-spot measurements enable efficient sorting and price evaluation of catalyst scrap throughout the recycling circuit.

View Product

Vanta for Environmental Assessments

Vanta handheld XRF analyzers for soils and sediment analysis provide fast, accurate environmental remediation and assessment data. Simple to use, Vanta analyzers are rugged for the most demanding field applications.

View Product

Vanta for Manufacturing Quality Control/Assurance

Vanta handheld XRF analyzers for manufacturing QA/QC provide highly specific material chemistry to quickly and accurately identify pure metals and alloy grades when material accuracy is critical.

View Product

Vanta for Mining & Geochemistry

Vanta handheld XRF analyzers for mining and geochemistry provide immediate on-site elemental analysis for geochemical exploration, mining grade control, ore processing, and remediation.

View Product

Vanta for Scrap Recycling

Vanta handheld XRF devices for recycling and scrap sorting are IP55 or 54-rated, depending on the model, to withstand rain, dirt, and dust and are drop tested using U.S. Department of Defense methods (MIL-STD-810G) to help prevent breakages and maximize uptime in the toughest scrap yards.

View Product

Vanta for PMI

Vanta handheld XRF analyzers for PMI provide highly specific material chemistry to quickly and accurately identify alloy grades to help ensure correct alloy installation in critical locations.

View Product

Vanta for Regulatory and Safety Screening

Vanta handheld XRF analyzers are used to ensure compliance with RoHS and local or international regulatory laws. Vanta analyzers provide on-the-spot chemical analysis of consumer products to quickly scan for Pb, Cd, Hg, Cr, and Br.

View Product

Vanta for Precious Metals Analysis

Vanta handheld XRF analyzers for precious metals provide fast, accurate alloy chemistry and karat classification for identifying gold, platinum, silver, and rhodium in jewelry analysis and car catalyst recycling.

View Product

Accessories

Evident offers a suite of optional accessories that help you maximize the efficiency of your Vanta analyzer in a range of applications.

Vanta Work Station

The portable Vanta Work Station is battery operated for testing on the go. A fully interlocked lid and 360-degree shielding make it convenient for bagged, prepped, and liquid samples or small objects, including jewelry and circuit boards. In this closed-beam setup, users operate the analyzer using Vanta PC software or the Vanta mobile app.

The portable Vanta Work Station is effective for a variety of applications:

  • Geo exploration
  • Mining process control
  • RoHS/consumer products
  • Environmental analysis

The Work Station’s stable platform enables longer test times. It gives you the freedom to start a test in the Work Station and complete other tasks while the Vanta instrument performs the analysis. You can be confident that the sample is stable and its position is reproducible, helping ensure high-quality data and efficient sample throughput.

Easy to Use

  • Simply click the Vanta analyzer into place, and release it with the press of a button
  • Balanced lid system to prevent slamming
  • Easy sample placement—no front wall or lip obstruction
  • Control the Vanta analyzer and transfer data wirelessly or via a USB cable

Portable

  • Battery or AC powered for benchtop or field use
  • Easy to transport and set up
  • Chamber and legs separate for easy storage
  • Optional carrying case

Designed for Safety

  • Fully shielded and interlocked chamber: 107 mm × 178 mm × 179 mm (4.2 in. × 7 in. × 7 in.)
  • Radiation warning LEDs are large, clear, and prominent

Small Footprint

  • 346 mm X 326 mm (14.4 in. × 13 in.)

Vanta Soil Foot

The Vanta Soil Foot provides a stable three-point support for the Vanta analyzer. This accessory facilitates hands-free analysis, making it convenient when longer test times are required.

Vanta Field Stand

When testing small items, such as samples in cups or bags, the Vanta Field Stand offers a lightweight, mobile test stand and shielded sample chamber. The Field Stand is easy to pack and convenient to use when you are away from your office.

Vanta Holster

Keep your Vanta analyzer safe and secure and within easy reach with the Vanta Holster. The Holster has a strap with a fastener to secure the instrument, MOLLE/PALS webbing for additional attachment options, and brass shielding.

Vanta Probe Shield

The Probe Shield provides additional shielding from backscattered radiation from testing low-density samples. This accessory provides an increased measure of protection by reducing the X-ray backscatter in the direction of the user during a test.

Vanta Hot Heel

For testing high-temperature piping or equipment up to 900 °F (480 °C), the Hot Heel minimizes heat transfer to the Vanta analyzer while reducing surface contamination. The Hot Heel kit includes high-temperature measurement windows.

Vanta Weld Mask

The Weld Mask prevents interference from the base metal when analyzing weld beads. This accessory replaces the Vanta analyzer’s faceplate and collimates the beam to a 3 mm wide slot for rapid analysis of weld beads.

Vanta Carry Case

Rugged, hard-shell case to securely transport your Vanta handheld XRF analyzer.

Vanta Work Station, Probe Shield, Hot Heel, and Weld Mask are not compatible with the Vanta Element XRF analyzer.

Resources

Application Notes

Case Studies

Insights

Product Resources