Notas de aplicación
Natural Gas Service Line Inspection Using Videoscopes
Background:
Natural Gas service lines connect the distribution line, which runs parallel to the road, with the meter on a residential or business property. Older service lines have the potential to corrode that may result in the leaking of natural gas in residential areas. These older lines are currently being replaced with plastic pipelines that have various diameters although the ½ inch (12.7 mm) diameter is most common. The fittings on the plastic pipe are welded by heat fusion. This process can create very large weld joints in the interior of the pipe, thereby dramatically reducing the ID at the bends.
Challenges:
- The reduction in ID at the weld joints prevents industrial videoscopes with large diameter insertion tubes scopes from fitting through. This weld joint also requires an articulating scope to navigate over a large weld bead.
- As cracks and general signs of wear are the main targets for this inspection, image clarity is crucial.
- A videoscopes having a large focal range is required to both see the interior wall and down the length of a pipe for navigation.
- Often the entire length of a long service line with limited access points needs to be inspected.
- Durability of the scope’s insertion tube and tip is crucial given the tight bends and articulation that is required.
Benefits:
- Evident has a 30 meter articulating scope in 8.5 mm (and 6 mm up to 18 m) to ensure the entire line is inspected even if the weld joints have a reduced ID.
- The TrueFeel feature (6 mm) and Pneumatic articulation (8.5 mm) provide great maneuverability even at 30 meters.
- In order to deliver a very clear and high quality image, LED’s at the tip or the powerful laser located in the base provide maximum light onto the weld area.
- Image clarity combined with a very wide focal range enables very efficient inspections of the interior wall as well as effortless navigation in long and curved pipes.
- Evident’s insertion tube construction is uncompromised. Despite the long length, you still get full durability to assure maximum uptime.
Related products
https://main--eds-evident-website--evident-scientific.aem.live/es/rvi-products/iplex-nx/
IPLEX NX
Este sistema videoscópico industrial de última generación engloba portabilidad, funciones avanzadas, facilidad de uso y durabilidad. Desde imágenes de alta calidad hasta operaciones de subsanación, la versatilidad de este videoscopio proporciona varios beneficios que van más allá de la experiencia.
https://main--eds-evident-website--evident-scientific.aem.live/es/rvi-products/iplex-gair/
IPLEX GAir
El videoscopio IPLEX GAir permite a los usuarios alcanzar objetivos de inspección lejanos de forma rápida y sencilla. Gracias a un alcance de 30 m (98 pies) y 20 m (65 pies), una articulación en aire, una orientación de imagen en vivo y otras características que favorecen la navegación precisa y adquisición de imágenes de alta calidad, maniobrar el videoscopio IPLEX GAir hasta los objetivos de los usuarios se ejecuta de manera rápida y eficiente.