채굴용 굴착기 스윙 샤프트 검사

Excavator

Surface mining often entails the use of large trucks and shovels including massive Dragline excavators in large scale operations to remove overburden to access coal and other deposits of desired resources. Due to the size of this equipment many of the components are very thick resulting in challenging applications for ultrasound. In addition the preferred test methods are with the components in place and in operation which can mean limited access to the areas that need inspected. Phased Array can offer many benefits to these inspections.

Shaft and Pin Inspections

There are many shaft and pin components throughout an excavator. One critical component is the Swing shaft. There may be multiple of these components throughout a single excavator. Common lengths can be 200” plus and diameters of 22” or more. With the component in place there is limited access to the multiple areas that may require testing for fatigue cracking and other defects. Conventional ultrasonics often utilize multiple angled wedges to inspect as much of the component as possible. Once defects are found the shafts are often removed and a complimentary 0 degree inspection from end to end of the shaft is conducted to further analyze the nature and extent of any defects. There are often many holes and other obstacles for a single beam 0 degree inspection. Areas of prime interest include known stress areas, tapers and reductions of diameter areas. Because Phased Array offers multi-angle inspections from a single probe the limited access inspection area can be inspected much better and images and data can be stored if defects want to be monitored.

Swing shaft in place and partially removed


Swing shaft in place and partially removed


Conventional and Phased Array Angle Beam Coverage. Red line shows possible limited access when component is in place

Inspection in field


Inspection i the field after shaft removed

Defect free shaft
Fatigue crack

Image from defect free shaft (corner of taper show) and fatigue cracked shaft

Related Shafts and Pins throughout a Dragline Excavator

Equipment Used

OmniScan SX or

Phased Array Probes and Wedges

Optional Software and Accessories

관련 제품


https://main--eds-evident-website--evident-scientific.aem.live/ko/omni-pc/

옴니PC 소프트웨어

이 새로운 소프트웨어는 옴니스캔 데이터 분석을 위한 가장 효율적이고 저렴한 선택으로, 옴니스캔 온보드 소프트웨어에 제공되는 것과 동일한 분석 도구를 갖추고 있으며, 개인용 컴퓨터에서 실행할 수 있는 유연성이 더해졌습니다.


https://main--eds-evident-website--evident-scientific.aem.live/ko/scanners/mini-wheel/

미니 휠 인코더

미니 휠 인코더는 스캔 축의 결함의 위치 결정 및 치수 결정에 사용됩니다. 데이터 수집과 프로브 이동을 동기화시킬 수 있습니다. 또한 방수성이며, Evident 표준 PA 쐐기와 호환됩니다.


https://main--eds-evident-website--evident-scientific.aem.live/ko/omniscan-sx/

옴니스캔 SX

단일 그룹인 경량 옴니스캔 SX는 읽기 쉬운 8.4인치(21.3cm) 터치 스크린을 갖추고 있으며, 비용 효율적인 솔루션을 제공합니다. 옴니스캔 SX는 SX PA와 SX UT의 두 가지 모델로 제공됩니다. SX PA는 UT 전용 SX UT와 마찬가지로 P/E, P-C 또는 TOFD 검사를 위한 재래식 UT 채널을 장착한 16:64PR 장치입니다.