탄소강 용접부의 자분 탐상 검사 대안으로서의 와전류

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds

Carbon Steel Weld Inspection

Magnetic particle inspection is used to help monitor the integrity of welded pipes and pressure vessels. This method was used for decades, primarily because of its portability and ease of use. It is a common industry practice to use specifically-designed oil and water-based carriers for magnetic particles, adding extra cost for chemicals and chemical waste disposal. In addition, this method also requires paint removal and repainting, adding additional cost to the inspection.

Eddy current inspection is an economical, nondestructive alternative to magnetic particle inspection. Eddy current inspection is fast, reliable, easy to use, and can inspect directly through painted surfaces. With eddy current, inspectors no longer have to strip and repaint pipes and vessels. As an added feature, eddy current makes it easy to record the defect length and depth.

Benefits of Eddy Current Array for Weld Inspection Compared to Magnetic Particle:

The inspection process using eddy current technology is fast, and the preparation is kept to a minimum—no intensive cleaning or paint removal is required. Eddy current inspection is also effective in most weather conditions including rain, heat, and cold. For easy post-processing analysis and data archiving, setup files can be saved and recalled for the next job. In addition, report files can be easily created directly from the instrument.

New Software Designed for Weld Applications

Eddy Current Array (ECA) Solution — OmniScan® Instruments

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 1: The Omniscan MX flaw detector with the MagnaFORM probe.

New ECA Probes Using Dynamic Lift-Off Compensation Technology

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 2: The MagnaFORM probe.

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 3: The MagnaFORM probe unassembled.

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 4: The probe’s interchangeable wedges.

Ready for Scanners

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 5: Image of MagnaFORM probe mounted on scanner

New Defect Depth Evaluation Tool

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 6: A screen shot of the flaw detector’s measurement tools.

Reliable Defect Detection

The probe’s flexible PCB technology combined with dynamic lift-off compensation technology enables the solution to detect defects in all areas of the weld.

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 7: The defects located during a weld inspection.

Instant Reporting

The OmniScan MX flaw detector features built-in reporting at the touch of a key. Reports can also be configured and customized by advanced users.

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds

Figure 8: An example of the first page of an OmniScan report.

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds

Figure 9: The second page of an OmniScan report.

Easy Archiving

Archiving inspection data files is easy, simply press a key during acquisition or analysis to store the data on the instrument’s memory card.

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 7: The defects located during a weld inspection.

관련 제품


https://main--eds-evident-website--evident-scientific.aem.live/ko/phasedarray/omniscan-x3/

옴니스캔 X3 Series

OmniScan ™ X3 시리즈의 모든 결함 탐상기는 완전한 위상 배열 툴박스입니다. 혁신적인 TFM 및 고급 PA 기능은 강력한 소프트웨어 도구와 간단한 워크 플로우로 생산성을 향상시키는 동시에 결함을 확실하게 식별하는 데 도움이됩니다.


https://ims.evidentscientific.com/ko/flaw-detectors/eddy-current-array

배열 와전류 프로브

배열 와전류 프로브는 부식 감지, 마찰 교반 용접 검사, 표면 및 표면 아래 감지를 통해 검사 프로세스를 가속화합니다.


https://main--eds-evident-website--evident-scientific.aem.live/ko/omniscan-eca/

옴니스캔 MX ECA/ECT

와전류 배열 시험 검사를 수행합니다. 테스트 구성은 브리지 또는 송수신 모드에서 작동하는 32개의 센서 코일(외부 멀티플렉서 사용 시 최대 64개)을 지원합니다. 동작 주파수는 20Hz에서 6MHz까지이며, 동일한 수집에서 여러 주파수를 사용할 수 있습니다.