XRF Analysis

Vanta for Precious Metals Analysis

Contact Us

Introducing Vanta Max and Core

Meet the Next-Generation Vanta™ XRF Analyzers

Learn More

Vanta for Precious Metals Analysis

When accuracy and confidence count, Vanta™ handheld XRF analyzers provide immediate, on-site elemental measurements for analyzing precious metals including gold, platinum, silver, and rhodium.

Vanta handheld XRF analyzers for precious metals analysis offer the flexibility for a variety of applications including:

  • Jewelry analysis
  • On-the-spot analysis of gold karat percentage
  • Car catalyst recycling
  • Gold bar analysis
New: Affordable Light Element ID with the
Vanta Element-S Analyzer

Platinum Group Metals Analysis in Car Catalyst Recycling

Learn More

Rugged

Vanta analyzers are durable for increased uptime and a low cost of ownership.

Vanta analyzers are IP55 rated* to withstand rain, dirt, and dust and are drop tested using U.S. Department of Defense methods (MIL-STD-810G) to help prevent breakages and costly repairs.

Vanta analyzers can withstand a temperature range of -10 °C to 50 °C (14 °F to 122 °F), so you spend less time waiting for your analyzer to cool, even in hot environments.**

The tough Kapton® window helps protect the detector from damage and costly repairs.

* M Series analyzers are IP54 rated.
** With optional fan. Operated continuously at 33 °C without the fan.

Revolutionary

The Vanta Series’ Axon™ technology uses ultra-low-noise electronics, enabling higher X-ray counts per second for fast, accurate, and repeatable results.

Axon technology coupled with a new quad-core processor make Vanta analyzers remarkably responsive, pushing the limits of performance, so you get the best results in the least amount of time.

Axon technology provides test-to-test and instrument-to-instrument repeatability, so your first test is the same as your last test no matter what instrument you may use.

Productive

Vanta analyzer’s customizable interface is easy to use and intuitive, so even users with minimal experience can be trained quickly. Users can access most features from the main menu in just 1 or 2 steps. Other features include:

  • Grade Match Messaging guides the operator with customizable instructions.
  • Data management is easy with GPS and optional Wireless LAN.
  • The onboard aiming camera helps create a record of the material analyzed.

Specifications

Dimensions (W x H x D)
Max and Core: 10.4 × 29.6 × 24.1 cm (4.1 × 11.6 × 9.5 in.)
Weight
Max: 1.9 kg (4.17 lb) with battery, 1.67 kg (3.67 lb) without battery
Core: 1.85 kg (4.06 lb) with battery, 1.62 kg (3.56 lb) without battery
Excitation Source
4-watt X-ray tube with application-optimized anode material: rhodium (Rh) or silver (Ag) Max (Rh), Core (Ag): 8-50 KV; Core (Rh): 8–40 KV
Primary Beam Filtration
Max and Core: 8-position autoselected filter per beam per mode; optional collimation to 3 mm diameter beam spot
Detector
Max: Large-area silicon drift detector with graphene window
Core: Silicon drift detector with graphene window
Power
Removable 14.4 V Li-ion battery (with hot-swap capability on Max only) or 18 V power transformer 100–240 VAC, 50–60 Hz, 70 W max
Display
800 × 480 (WVGA) LCD with capacitive touch screen supporting gesture control
Operating Environment
Temperature range for Max and Core: -10 °C to 50 °C (14 °F to 122 °F), and continuous full duty cycle with optional fan
Humidity: 10% to 90% relative humidity non-condensing
Drop Test
Military Standard 810-G 4-foot (1.3 M) drop test
IP Rating and Detector Shutter
Vanta Max: IP54* dust protected and protected against water splashing from all directions
Vanta Core: IP55* dust protected and protected from low-pressure water jets from all directions
Max and Core: Solid detector shutter to help prevent detector damage
*In-use position
Pressure Correction
Max and Core: Built-in barometer for automatic altitude and air density correction
GPS
Max: Embedded GPS / GLONASS receiver
Operating System
Linux cloud enabled with user fleet manager capability
Data Storage
microSD™ slot with removable 1 GB industrial SD card included
USB
(2) USB 2.0 Type-A ports for accessories such as Wi-Fi®, Bluetooth®, and USB flash drives
(1) USB 2.0 Type Mini-B port for connection to computer
Wi-Fi®
Supports an 802.11 b/g/n (2.4 GHz) cable optional USB adapter
Bluetooth®
Supports Bluetooth® with an optional USB adapter
Aiming Camera
Full VGA CMOS camera (optional)
Panorama Camera
13-megapixel CMOS camera with autofocus lens (optional)
Warranty
Max and Core: Three-year warranty
Selected Optional Accessories
Max and Core: Field Stand, Soil Foot, Holster, Work Station, Weld Mask, Hot Heel, and Probe Shield

--- *High temperature performance may vary due to electrical component availability.

Vanta for Car Catalyst Recycling

Vanta analyzers provide excellent performance when measuring precious metals in catalytic converters. Combustion engine automobiles are equipped with catalytic converters that help reduce harmful emissions such as carbon monoxide (CO), hydrocarbons (HC) and nitrogen oxides (NOx). Certain chemical reactions in the converter transform the harmful substances into carbon dioxide (CO2), water (H2O) and nitrogen (N). To optimize and speed up these reactions, catalyst elements, such as the three platinum group metals (PGM) platinum (Pt), palladium (Pd), and rhodium (Rh), are used in the converters. Because of the value of these metals, they are recycled.

handheld xrf for Car Catalyst Recycling

Car Catalyst Recycling

Vanta handheld XRF analyzers provide convenient, on-the-spot measurements of automotive catalysts with high precision and accuracy for:

  • Rapid identification of worthless monoliths (unloaded or washed-out).
  • Fast sorting of catalyst converters of different value levels to recover the precious metals Pt, Rh, and Pd.
  • Precise PGM concentration in minutes for price calculation.

Vanta analyzers also provide high-quality results for additional catalyst metals such as titanium (Ti), chromium (Cr), manganese (Mn), iron (Fe), nickel (Ni), copper (Cu), zinc (Zn), lead (Pb), bismuth (Bi), strontium (Sr), zirconium (Zr), tungsten (W), selenium (Se), and cerium (Ce).

Applications

Vanta analyzers provide fast results in a diverse range of applications. Application-specific software features enable operators to get the most out of their analyzers with simplified report creation and traceable results.

Vanta for Car Catalyst Recycling

Vanta™ handheld XRF analyzers provide fast, accurate measurement of the valuable platinum group metals (PGMs) palladium (Pd), platinum (Pt), and rhodium (Rh) found in car catalytic converter material. On-the-spot measurements enable efficient sorting and price evaluation of catalyst scrap throughout the recycling circuit.

View Product

Picture 1561794065, Picture, Picture

Vanta for Environmental Assessments

Vanta handheld XRF analyzers for soils and sediment analysis provide fast, accurate environmental remediation and assessment data. Simple to use, Vanta analyzers are rugged for the most demanding field applications.

View Product

Picture 1396715661, Picture, Picture

Vanta for Manufacturing Quality Control/Assurance

Vanta handheld XRF analyzers for manufacturing QA/QC provide highly specific material chemistry to quickly and accurately identify pure metals and alloy grades when material accuracy is critical.

View Product

Vanta for Mining & Geochemistry

Vanta handheld XRF analyzers for mining and geochemistry provide immediate on-site elemental analysis for geochemical exploration, mining grade control, ore processing, and remediation.

View Product

Vanta for Scrap Recycling

Vanta handheld XRF devices for recycling and scrap sorting are IP55 or 54-rated, depending on the model, to withstand rain, dirt, and dust and are drop tested using U.S. Department of Defense methods (MIL-STD-810G) to help prevent breakages and maximize uptime in the toughest scrap yards.

View Product

Vanta for PMI

Vanta handheld XRF analyzers for PMI provide highly specific material chemistry to quickly and accurately identify alloy grades to help ensure correct alloy installation in critical locations.

View Product

Vanta for Regulatory and Safety Screening

Vanta handheld XRF analyzers are used to ensure compliance with RoHS and local or international regulatory laws. Vanta analyzers provide on-the-spot chemical analysis of consumer products to quickly scan for Pb, Cd, Hg, Cr, and Br.

View Product

Vanta for Precious Metals Analysis

Vanta handheld XRF analyzers for precious metals provide fast, accurate alloy chemistry and karat classification for identifying gold, platinum, silver, and rhodium in jewelry analysis and car catalyst recycling.

View Product

Accessories

The Vanta™ analyzer is our most advanced handheld X-ray fluorescence (XRF) device. IP certified and drop tested, the robust Vanta XRF analyzer provides you with rapid, accurate element analysis for laboratory-quality results in the field.

Evident offers a suite of optional accessories that help you maximize the efficiency of your Vanta analyzer in a range of applications.

https://adobeassets.evidentscientific.com/content/dam/video/videolibrary/videos/VANTA_WORKSTATION_SUBTITLEMASTER_rev2.mp4

Vanta Work Station

The portable Vanta Work Station is battery operated for testing on the go. A fully interlocked lid and 360-degree shielding make it convenient for bagged, prepped, and liquid samples or small objects, including jewelry and circuit boards. In this closed-beam setup, users operate the analyzer using Vanta PC software or the Vanta mobile app.

The portable Vanta Work Station is effective for a variety of applications:

  • Geo exploration
  • Mining process control
  • RoHS/consumer products
  • Environmental analysis

The Work Station’s stable platform enables longer test times. It gives you the freedom to start a test in the Work Station and complete other tasks while the Vanta instrument performs the analysis. You can be confident that the sample is stable and its position is reproducible, helping ensure high-quality data and efficient sample throughput.

Easy to Use

  • Simply click the Vanta analyzer into place, and release it with the press of a button
  • Balanced lid system to prevent slamming
  • Easy sample placement—no front wall or lip obstruction
  • Control the Vanta analyzer and transfer data wirelessly or via a USB cable

Portable

  • Battery or AC powered for benchtop or field use
  • Easy to transport and set up
  • Chamber and legs separate for easy storage
  • Optional carrying case

Designed for Safety

  • Fully shielded and interlocked chamber: 107 mm × 178 mm × 179 mm (4.2 in. × 7 in. × 7 in.)
  • Radiation warning LEDs are large, clear, and prominent

Small Footprint

  • 36.6 mm × 33 mm (14.4 in. × 13 in.)

Other Vanta Accessories

Vanta Holster

Keep your Vanta analyzer safe and secure and within easy reach with the Vanta Holster. The Holster has a strap with a fastener to secure the instrument, MOLLE/PALS webbing for additional attachment options, and brass shielding.

Vanta Holster

Vanta Transport Case

Rugged, hard-shell case to securely transport your Vanta handheld XRF analyzer.

Vanta Work Station, Probe Shield, Hot Heel, and Weld Mask are not compatible with the Vanta Element XRF analyzer.

Resources

Videos

Product Resources

Insights