Products
Wire Encoder
Acquire high-quality phased array data with high positioning accuracy thanks to the wire encoder’s simple streamlined design, enabling you to focus on handling the probe. It installs quickly on both ferromagnetic and nonferromagnetic surfaces.Acquire high-quality phased array data with high positioning accuracy thanks to the wire encoder’s simple streamlined design, enabling you to focus on handling the probe. It installs quickly on both ferromagnetic and nonferromagnetic surfaces.
SteerROVER
The SteerROVER is a fully automated, steerable motorized scanner capable of performing weld inspection in remote locations. It can mount phased array as well as TOFD-P/E probes for inspection of circumferential or longitudinal welds.
WeldROVER™ Scanner
The WeldROVER scanner is designed to make fast, efficient phased array inspections on ferromagnetic piping or vessel girth welds and long seams with minimal training and setup time.
HST-Lite Scanner
The new HST-Lite scanner is the perfect choice for cost-effective, one-channel TOFD inspections when signal quality is important. The combination of magnetic wheels and spring-loaded probe holders offer the stability required to perform high quality, one-line inspections. The scanner can be operated using only one hand, and will attach to ferromagnetic surfaces even when in an upside-down position.
Mini-Wheel Encoder
The Mini-Wheel Encoder is used for the positioning and dimensioning of defects in the scan axis. It can synchronize data acquisition with probe movement. It is also waterproof and compatible with Evident standard PA wedges.
VersaMOUSE Scanner
The VersaMOUSE™ is a scanner designed for linear encoded scans with a phased array probe. The integrated indexing button makes it ideal for 2-D mapping applications such as CFRP flat panel and corrosion inspections. The VersaMOUSE can perform an encoded one-line scan, followed by indexing of the position in the perpendicular direction. Another one-line scan can then be performed and juxtaposed to the previous scan. This process is repeated to produce a complete 2D map of the area of interest.
HSMT-Flex Scanner
Designed with a central articulation joint, the HSMT-Flex™ scanner is intended for manual, encoded inspection of circumferential welds on pipes with outside diameters of 114.3 millimeters (4.5 inches) and larger, accommodating up to eight probes. The scanner is available in both standard and high-temperature models and can be equipped with a ScanDeck™ module. Its modular design allows for quick reconfiguration using only tool-free mechanisms.
ChainSCANNER
The ChainSCANNER™ solution facilitates manual inspection of pipes with outside diameters (OD) ranging from 76 mm to 965 mm (3 to 38 in.) Held by chain links instead of magnetic wheels, the scanner is well suited for weld or corrosion inspection on different types of materials using ultrasonic testing (UT), time-of-flight diffraction (TOFD), and phased array (PA) technologies.
COBRA Scanner
The COBRA™ manual scanner combined with the OmniScan X4 flaw detector is used to perform circumferential welding inspections on small-diameter pipes. The COBRA small-diameter scanning unit can hold two PA probes to inspect pipes with ODs ranging from 0.84 to 4.5 in.
HSMT-Compact Scanner
The HSMT-Compact is a manual one-axis encoded scanner. In particular, it is light and small, and also versatile. It can be used (with up to 4 probes) on plates and for circumferential scans on pipes as small as 4.5 in. OD pipes.