Risorse

Application Notes

Contatti

Cracking in Ceramic Diesel Particulate Filters

Application
Detection of internal cracking in ceramic diesel particulate filters.

Background
The use of ceramic particulate filters is well established as a method for removing environmentally dangerous soot and similar particulates from diesel engine exhaust, especially for diesel engines used in trucks and buses. These filters have the form of large cylinders, approximately 100 mm to 300 mm (4 in. to 12 in.) in diameter and 150 mm to 350 mm (6 in. to 14 in.) high. They are commonly made of cordierite, silicon carbide, or ceramic in a fine honeycomb pattern. As the hot exhaust is forced through the porous filter under pressure, soot particles collect on the surfaces of the honeycomb channels where they then break down or oxidize due to heat.
EPOCH XT testing ceramic

These complex ceramic structures can potentially crack during manufacturing, handling, or in service, causing reduced performance or failure that can cause both environmental and engine damage. Ultrasonic testing can quickly and nondestructively detect internal cracking in both new and used ceramic filter elements. The technique usually requires access to only one end of the cylinder.

Equipment
This test can be performed with both conventional flaw detectors and phased array instruments Any of the Epoch-series flaw detectors (, , EPOCH 650 or ) can be used with a low frequency contact transducer such as an A601S-RB or V601-RB (500 KHz). The OmniScan SX can also be used with the aforementioned transducers. A soft polymer membrane on the face of the transducer is used to couple sound energy into the filter without the need for liquid couplants that could be difficult to remove. The Advanced Filter option (standard on the ) can be helpful for improving signal-to-noise when testing larger filters by improving the instrument's low frequency response. Phased array testing can be performed with the OmniScan or and 1.5 MHz probes such as the 1.5L16-A4.

Procedure
Using firm hand pressure, the transducer is coupled to the end of the filter. High frequency sound energy propagating as plate waves travels through the ceramic honeycomb, reflecting off the far end if there are no discontinuities. If there is a crack parallel to the end surface, an echo will be received ahead of the point on the display representing the far end of the filter. If there is a crack that is tilted with respect to the ends, there may be no direct reflection but the echo from the far end will disappear.

In the example below representing a setup with a flaw detector and an A601S-SB transducer, the left screen image represents a typical echo pattern from an undamaged filter. The peaks at the left side of that waveform represent reverberations of the outgoing sound pulse, and the echo at the right side represents the reflection from the far end. There should be no significant echoes in the zone in the middle that is marked by the red gate. The right screen image represents an echo pattern from a filter that is cracked just past its midpoint. The backwall echo to the right of the gate has disappeared because sound energy is no longer reflecting from the far wall. The transducer can be moved to as many points as desired on the face of the filter to check for cracks at other locations.

Typical Backwall Echo from Good Filter

Typical Backwall Echo from Good Filter

Typical Midwall Echoes from Cracked Filter

Typical Midwall Echoes from Cracked Filter

The specific instrument setup for each type of filter should be established through the use of a known good setup standard that is used to optimize the echo from the far end. By identifying the echo pattern from a good filter and looking for changes, a trained operator can quickly and reliably identify echo variations that correspond to internal cracks.

Phased Array Testing

OmniScan Testing
Phased Array can offer cross-sectional imaging of filters from either sectorial or linear scans. This can aid operator visualization of flaws. Automated testing has also been implemented using larger array probes and specialized fixturing.

Prodotti per l'applicazione

OmniScan X3 Series

Ogni rilevatore di difetti della serie OmniScan™ X3 rappresenta uno strumento phased array completo. L’innovativo TFM e le avanzate funzionalità PA facilitano l’identificazione affidabile di difetti mentre i potenti strumenti software e i flussi di lavoro semplificati migliorano la produttività.

OmniScan MX PA

L'OmniScan PA effettua delle ispezioni phased array manuali e automatizzate. Offre tutte le funzioni di visualizzazione dell'A-scan, B-scan, S-scan e C-scan oltre all'avanzata capacità di elaborazione di dati in tempo reale. Configurazione degli elementi 16:128 oppure 16:16M, 16:64M, 32:32 e 32:128

OmniScan SX

Lo strumento OmniScan SX, leggero e a gruppo singolo, integra uno schermo tattile a alta leggibilità da 8,4" e permette la realizzazione di soluzioni in modo economicamente vantaggioso. L'OmniScan SX è disponibile in due modelli: SX PA e SX UT. L'SX PA è un'unità 16:64PR, la quale, come quella SX UT (solamente UT), integra un canale a UT convenzionali per le ispezioni impulso-eco, trasmissione-ricezione o TOFD.

EPOCH 650

L'EPOCH 650 è un rilevatore di difetti ad ultrasuoni convenzionali con eccellenti performance di rilevamento di difetti ed operatività per un ampia varietà di applicazioni. Questo intuitivo e robusto strumento è l'evoluzione del rilevatore di difetti EPOCH 600 di grande successo con delle funzionalità addizionali.