Borescope Solutions for Power Generation Inspection

Contact Us

Borescope for Turbine, Nuclear, Wind, and Balance of Plant Inspection

Regular maintenance of power generation plant equipment is essential to consistently produce stable and reliable power energy. Our wide range of power generation borescopes that we offer will be your optimal choice to meet the unique requirements of various power generation inspection applications, supporting safe and efficient power plant component inspections.

Talk to the Experts

https://adobeassets.evidentscientific.com/content/dam/tnm/videos/JetBlue_Iplex_060926.mp4

Power Generation Borescope Applications

Power Generation Turbines Inspection and Maintenance

In power generation plants and facilities, turbines are essential pieces of machinery. Steam and gas turbines operate under extremely high temperatures and pressures, and they require regular inspection and maintenance to ensure stable, safe, and efficient power generation. that need to be adequately maintained to ensure maximum your plants’ output stably and safely.

We offer a cost-effective and efficient visual inspection method to detect potential defects that could cause serious equipment damage, prolonged downtime, and significant financial losses. Our borescopes enable detailed power plant inspection of turbine components without the need for extensive disassembly, helping identify issues before they lead to costly failures.

Nuclear Power plant inspection and Maintenance

Periodic maintenance of nuclear power plants is critical health checkups to keeping equipment running safely, preventing issues from arising, and helping ensure safe and stable operation.

To inspect complex parts of nuclear power plant equipment, we offer visual inspection solutions for power plant component inspection, helping maintain the safety and reliability of equipment in both primary and secondary systems.to keep safety of your plant equipment in both primary and secondary systems.

Learn More

Wind Turbine Inspection and Maintenance

Wind turbine maintenance relies on the regular inspection of turbine parts, including enclosed and, difficult-to-access spaces. Without the proper equipment, wind turbine inspection can be difficult and time-consuming, resulting in extended downtime and interruptions to power generation.periods of downtime and interrupting energy generation.

We offer borescopes designed to provide easy visual inspection inside wind turbines, including wind turbine bearings and gearboxes. Equipped with an Oil Clearing Tip Adapter and oil-resistant insertion tube, our borescopes help maintain a clear view inside bearings while making cleanup after inspection quick and easy.

Learn More

Application Typical Constraint Recommended System
Gas and steam turbine blades, combustion chambers Defects must be sized and judged against limits IPLEX One with Swoptix 3D Measurement
Nuclear steam generators and reactor internals, where findings must be sized Radiation exposure plus dimensional data IPLEX One, radiation resistant with Swoptix 3D Measurement
Nuclear primary loop and long reach work Radiation exposure, operator standoff, distance to target IPLEX GAir, up to 30 m with remote operation to 100 m
Balance of plant piping, headers, heat exchangers, condensers Long runs, hard to know where you are in the pipe IPLEX GAir, up to 30 m, with insertion length indicator and gravity sensor
Wind turbine gearboxes and bearings Oil in the field of view, confined nacelle IPLEX G Lite or IPLEX GX/GT with oil clearing adapter
Boiler tubes and thermal plant walkdowns Portability, working at height, long shifts IPLEX G Lite, 1.15 kg weight
Mixed assets across one outage One system has to cover several jobs IPLEX One with interchangeable scopes

IPLEX One: Best In Class

The IPLEX One videoscope the 10th generation evolution of the IPLEX videoscope system. IPLEX One introduced a unified, software-driven platform that empowers inspectors to work faster, see more, and stay ahead – no matter the environment, application, or experience level.

Read More

IPLEX Gair: Long Range Analysis

The IPLEX GAir videoscope helps users reach far away inspection targets quickly and easily. With a 30 m (98 ft) and 20 m (65 ft) scope, air articulation, live image orientation, and other features that enable you to navigate precisely and capture high-quality images, the IPLEX GAir videoscope helps inspectors maneuver to targets quickly and efficiently.

Read more

IPLEX GX/GT: Most Versatile

With interchangeable insertion tubes and light sources, an 8 inch touch screen, and advanced imaging features, the IPLEX GX/GT videoscope delivers an optimal balance of versatility, imaging capabilities, and ease of use.

Read more

IPLEX G Lite/G Lite-W: Portable Scopes

The IPLEX G Lite industrial videoscope packs powerful imaging capabilities into a small, rugged body. Lightweight and able to go almost anywhere, users working in challenging applications have a remote visual inspection tool with the image quality and ease of use to get the job done.

Read more

IPLEX Long Scope Solution: Long Reach Areas

Industrial videoscope ideal for inspecting long reach areas such as heat exchangers, boiler tubes and water feed pipes. Accurate visual inspections of hard-to-reach areas up to 30 m deep are now easier than ever.

Read more

Power Generation Borescopes FAQs

What is a power generation borescope?
Power generation borescopes, or power generation videoscopes, are visual inspection devices used in the power generation industryies to inspect the internal components of equipment that structuresused in power generation facilities, namely including turbines, steam generators, and pipes. Power generation borescopes are used for regular visual inspection as part of power generation plant maintenance, helping to ensure safe and stable operation.for power generation plant maintenance to ensure its safe and stable operation.
What borescopes are required for power generation inspections?

The borescope required for power generation inspections depend on what you are inspecting and how you can reach it. For turbine inspections where defects need to be measured and assessed against a limitwork where defect has to be sized and judged against a limit, the IPLEX One video borescope offers Swoptix 3D Measurement, available for both 4 mm and 6 mm probes, with a 120-degree measurement field of view on the 6 mm probe.

If you need to inspect the components of a nuclear power plant, such as like steam generators located in radiation- contaminated areas, borescopes with a radiation-resistant design, such as the IPLEX One and IPLEX GAir video borescopes, can provide an effective inspection solution.

For long pipe runs, the IPLEX GAir videoscope reaches up to 30 m (98 ft), and its pneumatic articulation provides fine control of the tip angle at any insertion length. An insertion length indicator and gravity sensor help record the location of a defect inside the pipe, making it easier for follow- up with flaw detection or thickness gauging to return to the same location.

What are the features and benefits of power generation borescopes?
Power generation borescopes enable efficient visual inspection of power generation plant components, including turbines, steam generators, pipes, and wind turbine gearboxes. With power generation borescopes, you can easily view the interiors of power generation plant components to check for defects or faults without having to disassemble them. This enables regular power plant component inspection, helping these components are in safe working order and comply with applicable regulations.
What are the challenges of power generation visual inspection?
Access to the components is one of the most common challenges. Inspection points can sit deep inside machinery, be reached through small ports, and be a long way from where the operator can stand. In nuclear power plants, radiation exposure adds another challenge, limiting how long personnel can work in an area and requiring operators to maintain a greater distance from the equipment. Long pipe runs add a different problem: knowing the location of the inspection point once the borescope is inside. For wind turbine inspection, oil in a wind turbine gearbox can obscure the view. Each challenge requires a different inspection approach, which is why power generation inspection solutions include several borescope designs rather than a single solution.
What components can be inspected with a power generation borescope?
Power generation borescopes can be used to inspect a wide range of power plant components, including turbine blades, combustion chambers, steam generators, heat exchangers, pipes, valves, bearings, and gearboxes. They provide visual access to hard-to-reach areas without requiring extensive disassembly, making them an effective power plant inspection tool for identifying cracks, corrosion, wear, deposits, and other potential defects.

Power Generation Borescope Resources

Your Complete Guide to Remote Visual Inspection (RVI): 15 FAQs

march-2024-ryan-sterling-banner.jpg

Keeping a Safe Distance: Mitigating Radiation Exposure for Nuclear Plant Inspections Using Video Borescopes

september-2020-ryan-chen-banner.jpg

The Power of Foresight—Videoscopes Help Improve the Quality and Efficiency of Steam Turbine Inspection

Wind turbine inspection

Your Guide to Wind Turbine Inspection and Maintenance with a Videoscope

Improving Efficiency in Pipe Inspections Using Videoscopes