Oil & Gas Inspection Solutions

Integrity from Every Angle

In the oil and gas industry, integrity isn’t just a goal—it’s a non-negotiable standard that underpins safety, performance, and profitability across every phase of the operation.

From exploration to refining, unplanned downtime can result in massive losses and undetected defects can lead to catastrophic failures. In a high-stakes environment every decision must be driven by accurate, real-time data.

Evident’s advanced nondestructive testing (NDT) solutions deliver speed, precision, and reliability to meet the unique demands of upstream, midstream, and downstream applications. Whether inspecting drill components and risers, verifying weld integrity on pipelines, measuring wall thickness in high-wear areas, or monitoring corrosion in storage and processing infrastructure, our technologies are designed to detect flaws early, reduce risk, and maintain production continuity.

From phased array ultrasonic testing (PAUT) systems and weld inspection scanners to thickness gauging, flaw detection, and corrosion mapping tools, Evident empowers your teams to detect, diagnose, and act with confidence—no matter where you operate in the petrochemical supply chain.

Weld Inspection Solutions

Weld integrity is essential across all sectors of the oil and gas industry—from pipelines and pressure vessels to storage tanks and offshore platforms. We offer conventional and advanced UT solutions for both construction and in-service weld inspection, helping reduce risk and ensure safety in high-pressure, load-bearing environments. Our portfolio includes flaw detectors, automated and semi-automated scanners, and digital systems using PAUT, TOFD, TFM, PCI, and PWI. These technologies enable precise flaw detection and sizing, supporting consistent weld quality and operational reliability across upstream, midstream, and downstream applications.

Contact an Expert

Corrosion Detection Solutions

Corrosion detection is critical for ensuring the safety, efficiency, and compliance of oil and gas infrastructure. Evident offers high-performance nondestructive testing (NDT) solutions to detect corrosion in pipelines, storage tanks, pressure vessels, and structural assets. Our corrosion detection technologies—phased array ultrasonic testing (PAUT), total focusing method (TFM), time-of-flight diffraction (TOFD), and conventional ultrasonic testing (UT)—deliver accurate, data-rich inspections that help reduce downtime and extend asset life.

Contact an Expert

OmniScan™ X4 Ultrasonic Flaw Detector

OmniScan™ X4 Ultrasonic Flaw Detector

Advanced flaw detector using UT, PAUT, TOFD, TFM, and PCI for fast, accurate corrosion inspection in pipelines and components.

Learn More

EPOCH™ 650

EPOCH™ 650

Rugged and user-friendly flaw detector for conventional UT inspections of corrosion-critical assets in harsh field conditions.

Learn More

39DL PLUS Ultrasonic Thickness Gauge

The 39DL PLUS™ gauge is field-proven and reliable for virtually every ultrasonic thickness inspection. It works as a precision or corrosion thickness gauge to meet the challenges of demanding applications across industries, including maintenance, manufacturing, and energy production. With world-class ultrasonic capability, fast scanning speeds, and fully integrated wireless connectivity, this handheld gauge delivers results you can trust in a seamless workflow.

Learn More

Remote Visual Inspection Solutions

Internal defects in pipelines and process equipment can go undetected without direct visual access, increasing the risk of failures, unplanned downtime, and regulatory non-compliance. Our remote visual inspection (RVI) solutions—featuring advanced video borescopes—are designed to navigate hard-to-reach areas and deliver clear, high-resolution imagery for confident evaluations. From 3D image modeling to cloud-connected workflows, our digital tools accelerate inspections and enhance data-driven decision-making. Ideal for detecting clogging, corrosion, cracks, pinholes, and weld defects in piping, boilers, heat exchangers, valves, and rotating equipment throughout upstream, midstream, and downstream operations.

Request a Quote

IPLEX NX Videoscope

The IPLEX NX video borescope combines our highest-quality images with an intuitive user interface, ergonomic design, and durability for efficient inspection in nearly any environment.

Learn More

IPLEX GX/GT Videoscopes

With interchangeable insertion tubes and light sources, an 8 inch touch screen, and advanced imaging features, the IPLEX GX/GT videoscope delivers an optimal balance of versatility, imaging capabilities, and ease of use.

Learn More

iPLEX G Lite Video Borescope

The IPLEX G Lite industrial videoscope packs powerful imaging capabilities into a small, rugged body. Lightweight and able to go almost anywhere, users working in challenging applications have a remote visual inspection tool with the image quality and ease of use to get the job done.

Learn More

Alloy/Material Verification (PMI)

Using incorrect or substandard materials can lead to equipment failure, safety risks, and non-compliance. Evident Vanta™ handheld XRF analyzers deliver fast, accurate material analysis and alloy identification to support positive material identification (PMI) in welds, valves, and other refinery components. Vanta supports API RP 578 and API RP 939-C for material verification and sulfidation corrosion detection, as well as mercury screening in contaminated equipment. From upstream mudlogging and core analysis to downstream refinery maintenance and incoming warehouse verification, Vanta XRF ensures reliability at every stage. Vanta advanced software allows easy fleet management and streamlined data management and reporting.

Fast, accurate alloy ID for positive material identification (PMI) in piping, welds, and valves. Supports compliance with the American Petroleum Institute (API) Recommended Practice (RP) 578—Material Verification Program for New and Existing Alloy Piping Systems and API RP 939-C for sulfidation corrosion detection.

Request a Quote

Picture 1031646016, Picture

Vanta™ Handheld XRF Analyzers

Image 3, Picture

Vanta Element Handheld XRF Analyzer

The Vanta Element® handheld XRF analyzer series offers speed, ruggedness, and connectivity in two cost-effective models. The Vanta Element analyzer delivers affordable alloy ID, and the Vanta Element-S analyzer adds affordable light element detection. Both models feature easy handling and a modern intuitive interface for users of all skill levels. Perform material and grade ID in seconds and easily compare alloys for scrap recycling and metal manufacturing.

Learn More

Vanta Handheld XRF Analyzer

Instantly identify materials and their chemical composition from any location using the Vanta™ handheld XRF analyzer. The Vanta series delivers fast, accurate elemental analysis and material identification using smart and cloud-connected technology.

Learn More

Digital Solutions

Digital solutions are transforming how inspectors collect, manage, and interpret inspection data. Evident’s connected technologies enable seamless data acquisition, centralized storage, and remote collaboration across inspection teams. Our digital ecosystem—including cloud-based platforms, wireless data transfer, and automated reporting tools—enhances decision-making, improves traceability, and supports compliance with industry standards, all while streamlining the inspection workflow from field to office.

Image 4, Picture

Service and Support: A Partnership You Can Rely On

At Evident, our commitment to service is one of the key reasons why customers choose us. We stand behind every one of our NDT, RVI, and XRF technologies with responsive support and a global network of technical expertise. From comprehensive training and hands-on assistance to on-site service, we work as your partner to keep your equipment operating at peak performance—and your teams moving forward.

Wherever you inspect and whatever is at stake, you can count on us to be with you every step of the way.